NISSEI Measuring Equipment
-
Nissei DG-103
Digital SWR/Power Meter.
• Frequency Range: 1.6 - 60 MHz
• SWR Sensitivity: Minimum 300 mW
• Power Range: 300 mW - 300 Watt and 300 - 1200 Watt
• Maximum Power Rating: 1200 Watt
• Measurement Functions: Forward RF Power, Reflected RF Power, SWR
• Impedance: 50 Ω
• Power Supply: 9 - 14 VDC, 200 mA max
• Connectors: UHF-Female ( SO-239 ) -
Nissei K-SWR-1000
SWR/Watt Meter
• Frequency band: 26 - 30 MHz
• Measurable power range: 10 / 100 / 1.000 Watt
• Minimum power: 10 Watt
• Max Power: 1 KWatt
• Measurement functions: Forward Power, Reversed Power, SWR, PEP (active)
• Impedance: 50 Ω
• Connectors: UHF-Female (SO-239) -
Nissei TX-1202
Cross Needle SWR/Watt Meter
• Frequency band: 1.6 - 1300 MHz
• Measurable power range: 2 / 20 / 200 Watt
• Minimum power: 1 Watt
• MaxPower: 200 Watt HF/VHF and 20 Watt on 25 cm Band
• Measurement functions: Forward Power, Reversed Power, SWR, PEP (active)
• Impedance: 50 Ω
• Power Supply: 9 - 14 VDC, 200 mA max
• Connectors: UHF-Female (SO-239) and N-Female -
Nissei KSM-9000
External S-Meter
• Meter: Analogue
• Power Supply: 12 - 13.8 Volt
• Connection: Lead with 2.5 mm Connector -
Nissei RX-503
Cross Needle SWR/Watt Meter
• Frequency band: 1.8 - 525 MHz
• Measurable power range: 2 / 20 / 200 Watt
• Minimum power: 1 Watt
• Measurement functions: Forward and Reflected Power, SWR, PEP
• Impedance: 50 Ω
• Lighting power supply: 9 - 14 VDC, 200 mA max
• Connectors: UHF-Female (SO-239)(2 inputs + 2 outputs) -
Nissei TX-502
Cross Needle SWR-Power Meter.
• Frequency Range: 1.6 - 525 MHz
• SWR Sensitivity: Minimum 1 Watt
• Power Range: 2 Watt / 20 Watt / 200 Watt
• Maximum Power Rating: 200 Watt
• Measurement Functions: Forward RF Power, Reflected RF Power, SWR
• Connectors: UHF-Female ( SO-239 ) -
Nissei TX-101A
Cross Needle SWR/Watt Meter
• Frequency band: 1.6 - 60 MHz
• Measurable power range: 20 / 200 Watt / 2 KWatt
• Minimum power: 1 Watt
• Measurement functions: Forward Power, reversed Power, SWR, PEP (active)
• Impedance: 50 Ω
• Power Supply: 9 - 14 VDC, 200 mA max
• Connectors: UHF-Female (SO-239) -
Nissei RS-70
Digital SWR-Power Meter.
• Frequency Range: 1.6 - 60 MHz
• SWR Sensitivity: Minimum 1 Watt
• Power Range: 0 - 200 Watt
• Maximum Power Rating: 200 Watt
• Measurement Functions: Forward RF Power, Reflected RF Power, SWR
• Connectors: UHF-Female ( SO-239 ) -
Nissei RS-502
SWR-Power Meter.
• Frequency Range: 1.8 - 525 MHz
• SWR Sensitivity: Minimum 3 Watt
• Power Range: 5 Watt / 20 Watt / 200 Watt
• Maximum Power Rating: 200 Watt
• Measurement Functions: Forward RF Power, Reflected RF Power, SWR
• Connectors: UHF-Female ( SO-239 ) -
Nissei RS-50
Digital SWR-Power Meter.
• Frequency Range: 125 - 525 MHz
• SWR Sensitivity: Minimum 1 Watt
• Power Range: 0 - 120 Watt
• Maximum Power Rating: 120 Watt
• Measurement Functions: Forward RF Power, Reflected RF Power, SWR
• Connectors: UHF-Female ( SO-239 ) -
Nissei RS-102
SWR-Power Meter.
• Frequency Range: 1.8 - 200 MHz
• SWR Sensitivity: Minimum 3 Watt
• Power Range: 5 Watt / 20 Watt / 200 Watt
• Maximum Power Rating: 200 Watt
• Measurement Functions: Forward RF Power, Reflected RF Power, SWR
• Connectors: UHF-Female ( SO-239 ) -
Nissei RS-101
SWR-Power Meter.
• Frequency Range: 1.6 - 60 MHz
• SWR Sensitivity: Minimum 1 Watt
• Power Range: 30 Watt / 300 Watt / 3000 Watt
• Maximum Power Rating: 3000 Watt
• Measurement Functions: Forward Power, Reversed Power, VSWR
• Connectors: UHF-Female (SO-239) -
Nissei NS-60A *FS
Graphical HF Vector Antenna Analyzer
• Frequency range: 0,5 - 60 MHz
• Connector: BNC-Female -
Nissei DG-503
Digital SWR/Power Meter.
• Frequency Range: 1.6 - 60 and 125 - 525 MHz
• SWR Sensitivity: Minimum 1 Watt
• Power Range: 0 - 200 Watt
• Maximum Power Rating: 200 Watt
• Measurement Functions: Forward RF Power, Reflected RF Power, SWR
• Connectors: UHF-Female ( SO-239 )