Measuring Equipment
-
Aceco FC-6001p/n: ACECO FC6001
Handy RF Tracer, 1 MHz - 3 GHz Frequency Coverage, Ajustable Sensitivity, Alarm Click Beeper And 6 Section RSSI Bargraph Indicator
-
Nissei LP-230-Ap/n: NIS LP230A
Coaxial Lightning Surge Protection
• Frequency: DC-1500MHz
• Power: 100 Watt max
• Discharge voltage: DC 230V
• Impedance: 50 Ohms
• Connectors: N-Female / N-Female -
Nissei LP-230-Bp/n: NIS LP230B
Coaxial Lightning Surge Protection
• Frequency: DC-1500MHz
• Power: 100 Watt max
• Discharge voltage: DC 230V
• Impedance: 50 Ohms
• Connectors: N-Male / N-Female -
Nissei LP-350-Ap/n: NIS LP350A
Coaxial Lightning Surge Protection
• Frequency: DC-500MHz
• Power: 300 Watt max
• Discharge voltage: DC 350V
• Impedance: 50 Ohms
• Connectors: UHF-Female / UHF-Female -
Nissei LP-350-Bp/n: NIS LP350B
Coaxial Lightning Surge Protection
• Frequency: DC-500MHz
• Power: 300 Watt max
• Discharge voltage: DC 350V
• Impedance: 50 Ohms
• Connectors: UHF-Male / UHF-Female -
AOR MC-600p/n: AOR MC600
Impendance Matching Transformer
• Frequency Range: 10 kHz to 30 MHz
• Impendance: 50 Ohm / 600 Ohm
• Insertion Loss: Less than 3dB
• Connector: BNC-Female & Terminals for stripped wire -
Dosy FC-50-PSp/n: DOSY FC50PS
Frequency Counter, 6-Digit
• Range: 1.8 MHz to 50 MHz
• Display: Blue Light
• Designed for Single Side-Band Users
• Power Supply: Included -
Zetagi TM535 *FSp/n: ZETA TM535
SWR / Power Meter, Matcher
• Frequency Range: 1.5 - 30 MHz
• Power Range: 50 / 500 Watt
• Maximum Power Rating: 500 Watt AM/FM
• Antennas: Can be connected to 2 antennas
• Meter: Cross Needle, Illuminated by 12 VDC
• Connectors: UHF-Female (SO-239) -
Diamond SX-1100p/n: DIAM SX1100
Precision SWR-Power Meter
• Frequency Range: 4 Bands
.. 1.8-160 MHz / 430-450 MHz / 800-930 MHz / 1240-1300MHz
• SWR Sensitivity: Minimum 1 Watt / 2 Watt
• Power Range: 5 Watt / 20 Watt / 200 Watt
• Maximum Power Rating: 70 Watt / 100 Watt / 200 Watt
• Measurement Functions: Forward RF Power, Reflected RF Power, SWR, PEP Monitor
• Meter Illumination: DC 13,8 Volt (11-15 VDC)
• Connectors: S1 is UHF-Female (SO-239), S2 is N-Female -
Diamond SX-600Np/n: DIAM SX600N
Precision SWR-Power Meter
• Frequency Range: 2 Bands
.. 1.8-160 MHz / 140-525 MHz
• SWR Sensitivity: Minimum 1 Watt / 4 Watt
• Power Range: 5 Watt / 20 Watt / 200 Watt
• Maximum Power Rating: 200 Watt
• Measurement Functions: Forward RF Power, Reflected RF Power, SWR, PEP Monitor
• Meter Illumination: DC 13,8 Volt (11-15 VDC)
• Connectors: S1 is UHF-Female (SO-239), S2 is N-Female -
Nissei TX-1202 *FSp/n: NIS TX1202
Cross Needle SWR/Watt Meter
• Frequency band: 1.6 - 1300 MHz
• Measurable power range: 2 / 20 / 200 Watt
• Minimum power: 1 Watt
• MaxPower: 200 Watt HF/VHF and 20 Watt on 25 cm Band
• Measurement functions: Forward Power, Reversed Power, SWR, PEP (active)
• Impedance: 50 Ω
• Power Supply: 9 - 14 VDC, 200 mA max
• Connectors: UHF-Female (SO-239) and N-Female -
Nissei DG-103 *FSp/n: NIS DG103
Digital SWR/Power Meter.
• Frequency Range: 1.6 - 60 MHz
• SWR Sensitivity: Minimum 300 mW
• Power Range: 300 mW - 300 Watt and 300 - 1200 Watt
• Maximum Power Rating: 1200 Watt
• Measurement Functions: Forward RF Power, Reflected RF Power, SWR
• Impedance: 50 Ω
• Power Supply: 9 - 14 VDC, 200 mA max
• Connectors: UHF-Female ( SO-239 ) -
Daiwa CN-501VMp/n: DAIW CN501VM
Cross Needle SWR and Power Meter
• Frequency Range: 140 - 525 MHz
• SWR Sensitivity: Minimum 4 Watt
• Maximum Power Rating: 20W/200W
• Connectors: UHF-Female (SO-239) -
Daiwa CN-901VMp/n: DAIW CN901VM
Cross Needle SWR and Power Meter.
• Frequency Range: 140 - 525 MHz
• SWR Sensitivity: Minimum 5 Watt
• Maximum Power Rating: 20W/200W
• Connectors: UHF-Female(SO-239) -
Daiwa CN-901Gp/n: DAIW CN901G
Cross Needle SWR and Power Meter.
• Frequency Range: 900 - 1300 MHz
• SWR Sensitivity: Minimum 0,4 Watt
• Maximum Power Rating: 2W/20W
• Connectors: N-Female -
Nissei KSM-9000p/n: NIS KSM9000
External S-Meter
• Meter: Analogue
• Power Supply: 12 - 13.8 Volt
• Connection: Lead with 2.5 mm Connector -
CG Antenna BL-04p/n: CGA BL04
QRP Series Balun
• 1:4 Balun, Typically for a dipole antenna
• Very compact size and light weight
• Input power up to 100W PEP
• Low insert loss -
Diamond SX-100p/n: DIAM SX100
Precision SWR-Power Meter.
• Frequency Range: 1.6 - 60 MHz
• SWR Sensitivity: Minimum 3 Watt
• Power Range: 30 Watt / 300 Watt / 3 KW
• Maximum Power Rating: 1.8 - 3.5 MHz is 1 KW and 3.5 - 60 MHz is 1.2 KW
• Measurement Functions: Forward RF Power, Reflected RF Power, SWR, PEP Monitor
• Connectors: UHF-Female ( SO-239 ) -
Nissei DG-503p/n: NIS DG503
Digital SWR/Power Meter.
• Frequency Range: 1.6 - 60 and 125 - 525 MHz
• SWR Sensitivity: Minimum 1 Watt
• Power Range: 0 - 200 Watt
• Maximum Power Rating: 200 Watt
• Measurement Functions: Forward RF Power, Reflected RF Power, SWR
• Connectors: UHF-Female ( SO-239 ) -
Nissei RS-101p/n: NIS RS101
SWR-Power Meter.
• Frequency Range: 1.6 - 60 MHz
• SWR Sensitivity: Minimum 1 Watt
• Power Range: 30 Watt / 300 Watt / 3000 Watt
• Maximum Power Rating: 3000 Watt
• Measurement Functions: Forward Power, Reversed Power, VSWR
• Connectors: UHF-Female (SO-239) -
Nissei RS-102p/n: NIS RS102
SWR-Power Meter.
• Frequency Range: 1.8 - 200 MHz
• SWR Sensitivity: Minimum 3 Watt
• Power Range: 5 Watt / 20 Watt / 200 Watt
• Maximum Power Rating: 200 Watt
• Measurement Functions: Forward RF Power, Reflected RF Power, SWR
• Connectors: UHF-Female ( SO-239 ) -
Nissei RS-50p/n: NIS RS50
Digital SWR-Power Meter.
• Frequency Range: 125 - 525 MHz
• SWR Sensitivity: Minimum 1 Watt
• Power Range: 0 - 120 Watt
• Maximum Power Rating: 120 Watt
• Measurement Functions: Forward RF Power, Reflected RF Power, SWR
• Connectors: UHF-Female ( SO-239 ) -
Nissei RS-502p/n: NIS RS502
SWR-Power Meter.
• Frequency Range: 1.8 - 525 MHz
• SWR Sensitivity: Minimum 3 Watt
• Power Range: 5 Watt / 20 Watt / 200 Watt
• Maximum Power Rating: 200 Watt
• Measurement Functions: Forward RF Power, Reflected RF Power, SWR
• Connectors: UHF-Female ( SO-239 ) -
Nissei RS-70p/n: NIS RS70
Digital SWR-Power Meter.
• Frequency Range: 1.6 - 60 MHz
• SWR Sensitivity: Minimum 1 Watt
• Power Range: 0 - 200 Watt
• Maximum Power Rating: 200 Watt
• Measurement Functions: Forward RF Power, Reflected RF Power, SWR
• Connectors: UHF-Female ( SO-239 ) -
Nissei TX-502p/n: NIS TX502
Cross Needle SWR-Power Meter.
• Frequency Range: 1.6 - 525 MHz
• SWR Sensitivity: Minimum 1 Watt
• Power Range: 2 Watt / 20 Watt / 200 Watt
• Maximum Power Rating: 200 Watt
• Measurement Functions: Forward RF Power, Reflected RF Power, SWR
• Connectors: UHF-Female ( SO-239 )